10 kVA stabilizer price list (2026)

PriceInput rangeTypeCoolingWindingModel
₹16,21090–300VRelayToroidalMuscleGrid 10 kVA mainline 90–300V
₹17,21050–270VRelayToroidalMuscleGrid 10 kVA mainline 50–270V
₹18,210100–500VRelayToroidalMuscleGrid 10 kVA mainline 100–500V
₹18,21090–300VRelayCopperMisterwatt 10 kVA mainline 90–300V, copper
₹29,14050–270VRelayCopperMisterwatt 10 kVA mainline 50–270V, copper
₹33,620130–270VRelayToroidalMuscleGrid 10 kVA mainline 130–270V
₹39,558140–270VServoAir cooledStandardMuscleGrid 10 kVA servo 140–270V, air cooled
₹47,500140–270VServoAir cooledCopperMuscleGrid 10 kVA servo 140–270V, air cooled, copper
₹55,951140–270VServoOil cooledStandardMuscleGrid 10 kVA servo 140–270V, oil cooled
₹69,500140–270VServoOil cooledCopperMuscleGrid 10 kVA servo 140–270V, oil cooled, copper

Live store prices, inclusive of GST. This table is rebuilt from our catalogue, so it is never out of date.

Why the same 10 kVA costs four times as much

1. Relay or servo — the single biggest jump

Our relay stabilizers run ₹16,210–₹33,620. Servo units start at ₹39,558. That step is the biggest single line in the table, and it buys you a different kind of correction.

A relay stabilizer switches between fixed transformer taps. Correction is instantaneous and the electronics are simple, but the output moves in steps — you land inside a safe band, not on an exact figure. For a fridge, TV, washing machine or air conditioner that is completely sufficient, and it is what the overwhelming majority of Indian homes should buy.

A servo stabilizer drives a motorised variac with a control circuit that continuously hunts for 230V, holding output to about ±1%. Correction is smooth rather than stepped. That matters for CNC machines, medical and laboratory equipment, lifts, printing presses and anything where a 15V step upsets the load. It is an industrial answer to an industrial problem, and paying servo money to protect a domestic fridge is money wasted.

2. Input voltage range

A stabilizer can only correct what it can catch. Our relay range covers 130–270V, 90–300V, 50–270V and 100–500V, and the wider the window the more winding and switching the unit needs.

Buy for the worst voltage you actually see, not the average. A narrow-range unit on a bad feeder spends the summer in cut-off.

3. Air cooled or oil cooled

Air-cooled units are lighter, cheaper and correct for domestic and light commercial duty. Oil-cooled units immerse the transformer, run far cooler under sustained full load, and last longer where the stabilizer works hard all day. In our servo range, oil cooling is the difference between ₹39,558 and ₹55,951.

4. Winding material

Copper windings have lower resistance than aluminium, so they run cooler and lose less energy as heat over a long life. In our servo range copper adds roughly ₹8,000–₹14,000. Our mainline stabilizers instead use a toroidal transformer — a doughnut-shaped core with lower losses, cooler running and much less hum than a conventional laminated core. Misterwatt is our full-copper-wound line.

What will a 10 kVA stabilizer actually run?

The house convention is watts = kVA × 800, so 10 kVA carries about 8,000 W. In practice that is a whole home: two air conditioners, a refrigerator, a water pump, lights, fans and electronics on one box at the mains.

LoadTypical running wattsStabilizer size
One 1.5-ton air conditioner1,200 – 1,600 W4 – 5 kVA
Two air conditioners2,500 – 3,200 W5 – 7 kVA
Whole 2BHK home3,000 – 5,000 W7 – 10 kVA
Whole 3–4BHK home + pump5,000 – 8,000 W10 kVA
Small shop or clinic5,000 – 8,000 W10 kVA

If you are protecting one air conditioner, 10 kVA is oversized and a 4–5 kVA unit is the right buy at a fraction of the cost.

Mainline or point-of-use?

A mainline stabilizer sits at the distribution board and protects every socket in the house from a single box. A point-of-use unit protects one appliance. If you already own three or four separate stabilizers, one mainline unit usually costs less in total, looks tidier, and means nothing gets forgotten. A 10 kVA unit is almost always bought as a mainline.

How to choose in four questions

  1. What is the lowest voltage you actually see? That picks your input range.
  2. Are the loads sensitive? Household appliances → relay. Industrial, medical or precision equipment → servo.
  3. How hard will it work? Occasional peaks → air cooled. All day at near full load → oil cooled.
  4. Total connected load? Divide watts by 800 to get the kVA you need, then round up one size.
Why buy from MuscleGrid

Frequently asked questions

What is the price of a 10 kVA stabilizer in India?

In our own range ₹16,210 to ₹69,500 including GST. Relay mainline units are ₹16,210–₹33,620; servo units start at ₹39,558. The difference is relay versus servo, input voltage range, air versus oil cooling, and winding material — not brand markup.

How many watts is a 10 kVA stabilizer?

About 8,000 W, using the house convention of kVA × 800. That covers a whole home including two air conditioners, a fridge, a pump and lighting.

Do I need a 10 kVA stabilizer for one air conditioner?

No. A single 1.5-ton air conditioner needs about 4–5 kVA. Buy 10 kVA when you are protecting the whole house from the mainline.

What is the difference between a relay and a servo stabilizer?

A relay stabilizer switches between fixed transformer taps and corrects in steps — instant, simple and economical, and correct for household appliances. A servo stabilizer drives a motorised variac to hold a sharp 230V ±1% continuously, which matters for industrial, medical and precision loads.

Should I buy an air cooled or oil cooled stabilizer?

Air cooled for domestic and light commercial duty. Oil cooled where the stabilizer runs near full load all day — it stays cooler and lasts longer.

Is a copper wound stabilizer worth the extra cost?

Copper has lower resistance than aluminium, so it runs cooler and wastes less energy over a long life. It is worth it on heavy continuous duty. Our mainline range instead uses a toroidal transformer, which lowers losses a different way.

What warranty do MuscleGrid stabilizers carry?

Three years, covering manufacturing defects and internal component failure, with service from our own centres in Delhi and Meerut.

Still stuck? Our support team fixes these issues every day — most by remote guidance, the rest by free doorstep pickup-repair-return under warranty.
Contact MuscleGrid Support →  ·  Register your warranty