MuscleGrid Titan Series Inverter — All Fault Codes & Warnings

Sourced from the official MuscleGrid manuals · updated 2026-08-13

This page covers the MuscleGrid Titan Series hybrid solar inverters (4.2 kW / 24V and 6.2 kW / 48V). A steady red LED with a code means a fault (the unit stops); a flashing indicator is a warning (the unit keeps running).

Fault 01Fault 02Fault 03Fault 04Fault 05Fault 06Fault 07Fault 08Fault 09Fault 51Fault 52Fault 53Fault 55Fault 57Fault 58Fault 59Warning 01Warning 02Warning 03Warning 04Warning 07Warning 10Warning 15Warning 16

01Fault 01: Fan is locked (when inverter is off), or fan fault

Titan Series (titan) FAULT CODE 01 — Fan is locked (when inverter is off), or fan fault. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 01. What to do: Replace the fan; ensure it spins freely and is connected.

02Fault 02: Over temperature, or NTC not connected well

Titan Series (titan) FAULT CODE 02 — Over temperature, or NTC not connected well. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 02. What to do: Internal component temp over 100–120 °C — check the unit's airflow isn't blocked and ambient isn't too hot; let it cool.

03Fault 03: Battery voltage is too high (battery over-charged)

Titan Series (titan) FAULT CODE 03 — Battery voltage is too high (battery over-charged). This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 03. What to do: Check battery type/quantity match the unit's spec; if it persists, return to the repair center.

04Fault 04: Battery voltage is too low

Titan Series (titan) FAULT CODE 04 — Battery voltage is too low. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 04. What to do: Re-charge the battery; if it won't hold charge, replace it.

05Fault 05: Output short-circuited, or over-temperature detected by internal converter components

Titan Series (titan) FAULT CODE 05 — Output short-circuited, or over-temperature detected by internal converter components. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 05. What to do: Check output wiring and remove any shorted/abnormal load; ensure airflow isn't blocked.

06Fault 06: Output voltage is too high

Titan Series (titan) FAULT CODE 06 — Output voltage is too high. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 06. What to do: Output abnormal (<190 V or >260 VAC): reduce the connected load; if it persists, return to repair.

07Fault 07: Overload time-out

Titan Series (titan) FAULT CODE 07 — Overload time-out. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 07. What to do: Inverter overloaded (>105–110%) and time elapsed: switch off some equipment to reduce load. If caused by high PV derating, reduce PV modules in series.

08Fault 08: Bus voltage is too high

Titan Series (titan) FAULT CODE 08 — Bus voltage is too high. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 08. What to do: Internal components fault — return to the repair center.

09Fault 09: Bus soft-start failed

Titan Series (titan) FAULT CODE 09 — Bus soft-start failed. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 09. What to do: Internal components fault — return to the repair center.

51Fault 51: Over current or surge

Titan Series (titan) FAULT CODE 51 — Over current or surge. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 51. What to do: Restart the unit; if the error recurs, return to the repair center.

52Fault 52: Bus voltage is too low

Titan Series (titan) FAULT CODE 52 — Bus voltage is too low. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 52. What to do: Internal fault — return to the repair center.

53Fault 53: Inverter soft-start failed

Titan Series (titan) FAULT CODE 53 — Inverter soft-start failed. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 53. What to do: Internal components fault — return to the repair center.

55Fault 55: Over DC voltage in AC output (output voltage unbalanced)

Titan Series (titan) FAULT CODE 55 — Over DC voltage in AC output (output voltage unbalanced). This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 55. What to do: Return to the repair center.

57Fault 57: Current sensor failed

Titan Series (titan) FAULT CODE 57 — Current sensor failed. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 57. What to do: Internal components fault — return to the repair center.

58Fault 58: Output voltage is too low

Titan Series (titan) FAULT CODE 58 — Output voltage is too low. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 58. What to do: Output abnormal (<190 V or >260 VAC): reduce the connected load; if it persists, return to repair.

59Fault 59: PV voltage is over the limitation

Titan Series (titan) FAULT CODE 59 — PV voltage is over the limitation. This is a FAULT: steady red Fault LED, the inverter STOPS and the LCD shows fault code 59. What to do: Reduce the number of PV modules in series so PV input is within spec.

01Warning 01: Fan is locked when inverter is on

Titan Series (titan) WARNING/ALARM CODE 01 — Fan is locked when inverter is on. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: Beeps 3× every second. What to do: Check the cooling fan is connected and spinning.

02Warning 02: Over temperature

Titan Series (titan) WARNING/ALARM CODE 02 — Over temperature. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: None. What to do: Reduce load; ensure airflow isn't blocked and ambient isn't too hot.

03Warning 03: Battery is over-charged

Titan Series (titan) WARNING/ALARM CODE 03 — Battery is over-charged. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: Beeps once every second. What to do: Check the charging settings / battery spec.

04Warning 04: Low battery

Titan Series (titan) WARNING/ALARM CODE 04 — Low battery. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: Beeps once every second. What to do: Re-charge the battery, or restore mains/PV to charge it.

07Warning 07: Overload

Titan Series (titan) WARNING/ALARM CODE 07 — Overload. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: Beeps once every 0.5 second. What to do: Reduce the connected load by switching off some equipment.

10Warning 10: Output power derating

Titan Series (titan) WARNING/ALARM CODE 10 — Output power derating. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: Beeps 2× every 3 seconds. What to do: Informational — output is being derated (e.g. high PV/temperature).

15Warning 15: PV energy is low

Titan Series (titan) WARNING/ALARM CODE 15 — PV energy is low. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: Beeps 2× every 3 seconds. What to do: Informational — insufficient solar; normal at low light.

16Warning 16: High AC input (>280 VAC) during BUS soft start

Titan Series (titan) WARNING/ALARM CODE 16 — High AC input (>280 VAC) during BUS soft start. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: None. What to do: Check the incoming mains/generator voltage is within range.

More from this manual

Warning E9: Battery equalization in progress

Titan Series (titan) WARNING/ALARM CODE E9 — Battery equalization in progress. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: None. What to do: Informational — equalization charging is running (lead-acid only).

Warning bP: Battery is not connected

Titan Series (titan) WARNING/ALARM CODE bP — Battery is not connected. This is a WARNING (not a fault): red LED FLASHES, the inverter KEEPS RUNNING. Audible: None. What to do: Check the battery wiring/connection.

BMS code 60

Titan Series (titan) BMS CODE 60 — After a successful BMS handshake, the battery is not allowed to charge OR discharge — the inverter stops both. An informational LCD code shown for lithium batteries after a successful BMS handshake. The lithium battery's BMS is protecting itself; check the battery state / BMS and let it recover.

BMS code 61

Titan Series (titan) BMS CODE 61 — Communication lost with the battery BMS (no signal for 1 min when not connected, or comms dropped after a successful connect — buzzer beeps). An informational LCD code shown for lithium batteries after a successful BMS handshake. Check the BMS communication cable (RS485/CAN) between battery and inverter.

BMS code 62

Titan Series (titan) BMS CODE 62 — After a successful BMS handshake, the battery is not allowed to charge — charging stops. An informational LCD code shown for lithium batteries after a successful BMS handshake. BMS is blocking charge (e.g. full / protection); informational, recovers on its own.

BMS code 70

Titan Series (titan) BMS CODE 70 — After a successful BMS handshake, the battery requests charging — the inverter charges. An informational LCD code shown for lithium batteries after a successful BMS handshake. Informational — normal BMS-requested charge.

BMS code 71

Titan Series (titan) BMS CODE 71 — After a successful BMS handshake, the battery is not allowed to discharge — discharge stops. An informational LCD code shown for lithium batteries after a successful BMS handshake. BMS is blocking discharge (e.g. low SOC / protection); recovers when the BMS permits.

Troubleshooting

Titan Series (titan) TROUBLESHOOTING. Unit shuts down during startup (LCD/LEDs/buzzer on for 3 s then fully off): Battery voltage is low (<1.91 V/cell). Re-charge the battery; replace if it won't hold. | No response at all after power-on: Battery far too low (<1.4 V/cell) or the internal fuse tripped. Contact the repair center to replace the fuse; re-charge or replace the battery. | Mains present but unit runs on battery (green LED flashing): Poor AC quality, OR AC wires too thin/long, OR wrong input-voltage-range setting, OR output priority is set to 'Solar First'. Check wiring/setting; set output priority to 'Utility First' if you want grid first. | Internal relay clicks on/off repeatedly (LCD/LEDs flashing): Battery is disconnected — check the battery wires are connected well.

Parallel-system fault codes (multi-inverter installs)

Titan Series (titan) PARALLEL-SYSTEM FAULT CODES (only in multi-inverter installs): 60 = Power feedback protection | 71 = Firmware version inconsistent | 72 = Current sharing fault | 73 = Inconsistent output-voltage settings across parallel units | 80 = CAN communication fault | 81 = Host (master) loss | 82 = Synchronization loss | 83 = Battery voltage detected different between units | 84 = AC input voltage/frequency detected different between units | 85 = AC output current unbalance | 86 = AC output mode setting is different between units. Note: in a SINGLE-unit install these numbers instead carry their normal fault/BMS meaning.

Settings: Output & input

Titan Series (titan) LCD SETTING — Output & input. Enter setup: press & hold ENTER 3 s; UP/DOWN to select a program; ENTER to confirm; ESC to exit. 00 Exit setting mode (ESC). 01 Output source priority: 'SUb' = Solar first (utility supplements when solar is insufficient); 'SbU' = SBU (solar first, then battery; utility only when battery drops to the low-voltage warning or the program-12 point). 02 Max total charging current (utility+solar): default 60 A, 10 A–max, 10 A steps. 03 AC input voltage range: 'APL' Appliances (90–280 VAC, default) / 'UPS' (170–280 VAC). 09 Output frequency 50 Hz (default)/60 Hz. 10 Output voltage 220/230(default)/240 V. 08 ECO 'SdS' off(default)/'SEn' on.

Settings: Battery type & charger priority

Titan Series (titan) LCD SETTING — Battery type & charger priority. 05 Battery type: AGM(default) / FLd Flooded / USE User-Defined / LIA (LIA-protocol lithium) / PYL Pylontech / t9F Techfine / GrO Growatt / LIb (LIB-protocol lithium) / LIC (3rd-party lithium). Lithium/protocol types auto-set programs 26/27/29 (LIA also 24). 16 Charger source priority: 'CSO' Solar first / 'SNU' Solar+Utility(default) / 'OSO' Only Solar. In battery mode only solar charges.

Settings: Charging voltages

Titan Series (titan) LCD SETTING — Charging voltages. 26 Bulk/Constant-Voltage (CV) charge: 24 V-system default 28.2 V [24–30 V]; 48 V-system default 56.4 V [48–60 V]; 0.1 V steps (settable only if User-Defined). 27 Float charge: 24 V default 27.0 V; 48 V default 54.0 V. 29 Low DC cut-off: 24 V default 21.0 V [20–26 V]; 48 V default 42.0 V [40–52 V]. 11 Max utility charging current: default 30 A, 2 A then 10 A–max, 10 A steps. CV must be higher than float.

Settings: Battery switch thresholds & alarms

Titan Series (titan) LCD SETTING — Battery switch thresholds & alarms. 12 Voltage point back to utility (SBU priority): 24 V default 23.0 V [22–25.5 V, 0.5 V]; 48 V default 46 V [44–51 V, 1 V]. 13 Voltage point back to battery mode (SBU priority): 24 V 'FUL'/27.0 V [24–29 V]; 48 V 'FUL'/54 V [48–58 V]. 24 Battery low-voltage alarm: 20–27 V (24 V system) / 40–54 V (48 V system). 18 Alarm control bON(default)/bOF. 22 Beeps when primary source interrupted AON(default)/AOF. 23 Overload bypass byd(default)/byE. 25 Record fault code FEN(default)/FdS. 19 Auto-return display ESP(default)/tEP. 20 Backlight LON/LOF.

Settings: Battery equalization (lead-acid only)

Titan Series (titan) LCD SETTING — Battery equalization (lead-acid only). Only when Flooded or User-Defined in program 05. 30 Equalization EEn / EdS(default). 31 Equalization voltage: 24 V default 29.2 V [24–30 V]; 48 V default 58.4 V [48–60 V]. 33 Equalized time 60 min [5–900]. 34 Equalized timeout 120 min [5–900]. 35 Equalization interval 30 days [0–90]. 36 Equalize immediately AEn/AdS(default) (LCD shows 'E9' while active). Do NOT equalize lithium batteries.

Settings: BMS & SOC settings (lithium)

Titan Series (titan) LCD SETTING — BMS & SOC settings (lithium). 37 BMS Function Switch OFF(default)/ON. 38 Battery SOC under-lock: default 10% — if BMS SOC drops below, the inverter shuts down to protect the battery. 39 Battery SOC turn-to-AC: default 20% — in battery-priority mode, forces mains charging when SOC below. 40 Battery SOC turn-to-DC: default 95% — resumes DC/battery mode when SOC above. 41 Battery restart SOC: default 50% — at power-on, SOC must exceed this to run.

Settings: Solar, grid-tie, scheduling & time

Titan Series (titan) LCD SETTING — Solar, grid-tie, scheduling & time. 43 Solar supply priority: 'bLU' charge battery first / 'LbU' power loads first. 44 Solar feed-to-grid: 'Grd' disable / 'GtE' enable. 45 Reset PV energy Nrt(default)/rSt. 46 AC-charger start time / 47 stop time [00:00–23:00]. 48 Scheduled AC output ON / 49 OFF [00:00–23:00]. 50 Country regulations Mode1 Ind/Mode2 GEn/Mode3 SAd/Mode4 PAr(default) (feed-in V/freq ranges). 51–55 Time set min/hour/day/month/year. 56 Grid-tie current 10 A (1 A steps). 57 External CT function. 58 Mains input power 150 W [10–500 W].

Settings: Dual (second) output

Titan Series (titan) LCD SETTING — Dual (second) output. 60 Dual output L2F disable(default)/L2O use. 61 Dual-output functional voltage point: 48 V default 44.0 V / 24 V default 22.0 V — second output cuts off below this (0.1 V steps). 62 Dual-output SOC point: default 15% (lithium) — cuts off below. 63 Dual battery voltage recover: default 52 V/26 V. 64 Dual battery SOC recover: default 50%/95%. 65 Discharge time on 2nd output: disable, 0–990 min [5 min]. 66 Dual recover delay 0–60 min. 67 Output open time / 68 Output stop time [0–23].

Products this guide covers

🛒
MuscleGrid Titan 4.2 kW Hybrid Solar Inverter (24V)
View product, price & warranty
🛒
MuscleGrid Titan 6.2 kW Hybrid Solar Inverter (48V)
View product, price & warranty

Other fault-code guides

Focus 6.2 kW (MG6500-48)
All fault codes for this series
Heavy Duty Series (3.6–6.2 kW)
All fault codes for this series
MG Hybrid range (1.5–10.2 kW)
All fault codes for this series
🔋
Lithium battery fault codes
JK BMS codes on the battery LCD
Still stuck? Our support team fixes these issues every day — most by remote guidance, the rest by free doorstep pickup-repair-return under warranty.
Contact MuscleGrid Support →  ·  Register your warranty